Heat Trap
For increased energy efficiency, some
water heaters have been supplied with
factory installed 3/4 in. NPT heat traps
in the hot outlet line and cold water
inlet line.
These heat traps may require a
minimum of one (1) 90° 3/4 in. NPT
elbow and may require an additional
90° 3/4 in. NPT elbow or a 3/4 in.
coupling depending on your installation
needs. See illustration of nipples and
heat traps on page 22.
For increased energy efficiency, this water heater has been supplied with a 2 3/8 in. section of T&P
insulation. Please install the insulation as shown below.
T&P Insulation Installation
Typical Side Connect T & P Arrangement.
Slip the insulation cover over the T&P
Valve through the center hole and align the
hole in the side with the opening of the T&P
Valve.
Ensure the T&P Valve opening is not
obstructed by the insulation.
Typical Top Connect T & P Arrangement.
DO
DO check inlet gas pressure to ensure that
it is within the range specified on the rating
plate.
DO provide adequate air for combustion
and ventilation as discussed in the Use and
Care Manual and the National Fuel Gas
Code.
DO maintain proper clearances to
combustibles as specified on the Instruction/
Warning Label.
DO ensure that the venting system
complies with the guidelines found in the
Use and Care Manual and National Fuel Gas
Code.
DO contact a qualified service technician
if the pilot or main burner will not stay lit.
The burner chamber is designed to be sealed
utilizing a gasket and tamper resistant screws.
DON’T
DON’T block or restrict Combustion
Air Inlet Openings located around the lower
portion of the water heater jacket.
DON’T remove the Burner Access Door
unless absolutely necessary. This should only
be done by a qualified service technician.
A new burner access door gasket must be
installed on any burner access door that has
been removed.
DON’T install this water heater where
standing water may occur. The base of the
water heater is meant to be mounted on a dry
surface.
DON’T operate the water heater if the
sight glass or pilot assembly grommet is
damaged or broken.
Pilot Assembly
Grommet
Sight Glass
During Installation of this water heater